Page 48 - professional-catering
P. 48

/ Electronic controls


                               HYGIENE
                               AND INFECTION CONTROL


                               Opens/closes automatically,               Energy savings
                               with no manual contact                    The electronic mixers and taps do not require much
                               DELABIE electronic mixers and taps are operated    energy to operate. For battery-operated models,
                               by infrared active pulse detection.       DELABIE has chosen infrared active pulse technology,
                               Flow opens when the detector senses hands    a low-power consumption model.
          Hygiene and infection control  and shuts off automatically when hands are removed   The infrared bean is emitted intermittently, saving
                               from the detection zone.                  energy while ensuring effective detection.
                               The absence of manual contact prevents the spread   Battery-operated models have an average lifespan
                               of germs by hand.                         of 350,000 cycles (i.e. 3 to 6 years) depending on
                                                                         the frequency of use. The Lithium batteries are widely
                               Anti-bacterial duty flush programme       available, affordable and recyclable.
                               If a mixer or tap is not used for prolonged periods   The exceptional hot water savings provided
                               of time, water stagnates in the pipework, which   by DELABIE’s mixers and taps also result in energy
                               promotes bacterial development (e.g. isolated    savings.
                               points-of-use, facilities closed during holidays, etc.).
                               DELABIE’s electronic mixers and taps have a duty   Environmental labels
                               flush programme.                          The water and energy saving performance of
          Reduced-stagnation solenoid   An automatic flush takes place for approximately   DELABIE’s electronic mixers and taps means that the
          valve                60 seconds every 24 hours after the last use   buildings achieve the highest performance standards
                               (programmable on some models).            for international rating schemes such as LEED,
                                                                         BREEAM or HQE.
                               Reduced-stagnation solenoid valve
                               Most solenoid valves on the market are fitted with
                               a rubber membrane behind which water stagnates   SPECIFICALLY DESIGNED FOR
                               and is not renewed. This can lead to bacterial growth.   COMMERCIAL ENVIRONMENTS
                               DELABIE has developed a technology without
                               a membrane (patented system).
                               With this piston-operated solenoid valve, water is   Easy to install
                               drained and renewed with every use which reduces   DELABIE’s products are easy to install and
                               niches where bacteria can develop.        adjustments are kept to a minimum in order to save
          No manual contact                                              time during installation.
                               The solenoid valve’s self-cleaning system with a
                               calibrated groove reduces the build-up of impurities.   • Independent electronic control unit:
           Conventional   DELABIE
             mixer    mixer    It’s slow closure also eliminates water-hammer.  BINOPTIC and TEMPOMATIC 2 models
             9 lpm    3 lpm                                                Depending on the model, the electronic control unit
             0%      90%                                                   offers the option to adjust the presence detection
                               90% WATER                                   distance, to change the operating mode (ON/OFF
                               AND ENERGY SAVINGS                          or automatic) and change the duty flush settings.
                                                                           The electronic control units are waterproof with
                                                                           diagnostic LEDs to facilitate servicing.
                               Water savings                             • Electronic unit and solenoid valve integrated
                               Compared to conventional mixers and taps,   in the body of the mixer/tap*:
                               DELABIE’s electronic mixers and taps offer maximum   TEMPOMATIC 4 model
                               water savings. They ensure the manager’s water bills   Can be installed on any isolated point-of-use,
                               can be reduced whilst preserving user comfort.  for new builds as well as renovation.
             4.8L    0.6L      • Automatic shut-off and split delivery     - 6V Lithium batteries*:
                                 The mixer or tap shuts off automatically when   There are no electrical connections required.
             32 sec  12 sec     hands are removed from the detection zone.    Simply connect the flexibles to the supply pipes
                                This removes the risk of waste through negligence.   in the same way as for a conventional mixer/tap.
          Water saving per use  The anti-blocking security activates to prevent the   No special adjustment is necessary, the mixer/tap
                                mixer or tap from flowing continuously. The flow   is ready to operate independently for 3 to 6 years.
                                time is reduced to the minimum necessary (wetting,   A red LED will flash to indicate that the battery life
                                rinsing).                                   is low. The batteries can be changed without shutting
                                                                            off the water supply or removing the mixer/tap.
                               • Flow rate regulated at 3 lpm
                         YEAR    DELABIE’s electronic mixers and taps are regulated   - 230/6V mains supply (plug in or recessed)*:
                                at 3 lpm, ensuring constant flow regardless of
                                                                            To operate, simply connect the flexibles to the
                                pressure variations in the system. The flow rate can    supply pipes and connect the electrical supply
              WARRANTY          be adjusted from 1.4 to 6 lpm.              to the mixer/tap via a plug and socket or recessed
                                                                            connection close to the basin.
                                                                            This does not require any specific maintenance.
                                                                         * Depending on model
                                                                         30-year warranty against any manufacturing defects.
                                                                         50 years repairability.







          46  Non-contact controls